Altium Designer 22.6.1 Build 34

Description

Altium Designer 22.6.1 Build 34

Schematic
49754 Find and Replace string substitution would cause an exception error when attempting to perform a partial string replacement. (BC:18053)
PCB
47715 Solder Mask openings for pads were not being displayed when viewing a mirrored embedded board in 3D.
49544 Clearance Boundaries would be displayed when trying to route track in a Keepout area whose Track and Copper restrictions had been disabled. (BC:8439)
49632 Pad Via libraries always opened with Imperial Display Units, regardless of the units chosen when the library was saved.
49633 When a new Pad template was added to a Pad Via Library, the Via Template Editor would incorrectly open instead of the Pad Template Editor.
49634 Pad Templates in the Properties panel were listed in the order they were added; they are now listed alphabetically.
49758 Additional checks have been added to the PCB Health Check Monitor to detect 'Unused xSignals' and 'Unused From-Tos'.
49887 For a specific PCB, an AV (Invalid GUID string) would occur when opening the Rules Editor and the board had been saved with the Rules displayed in Document View.
49963 AV occurred during Un-Routed Net DRC when a TH pad (hole size 0) was defined to only appear on a single layer, and was connected to a same net poly on that layer.
49999 When generating Gerbers for a specific PCB using the *.gbr file output format, mid layers and mechanical layers were empty. (BC:18483)
50080 The real (physical) height of a sub-stack was not being presented in the 3D view of the board.
50124 When adding one or more mechanical layers to the 'Other Layers' group, in the new Gerber Setup dialog, addition would only be to the first layer in the group.
Draftsman
45933 A Board Fabrication view of a panelized PCB was only displaying polygons on one board in the embedded array, instead of all boards.
Platform
31836 Specific STEP models would cause Altium Designer to crash when those components were on a board being loaded into a Multi-board Assembly. (BC:15232)
49954 It was possible to use the Clone and Open Project As Copy controls, in the Open Project dialog, when using a Viewer license of Altium Designer.
50070 The Storage Manager was not displaying Git merge commits, these are included now.
50355 The 'Workspace Library is empty' message was shown in the Components panel after refreshing if a search keyword is entered.
50402 The Edit command was not accessible in the Components panel when not connected to an Altium 365 Workspace.
Data Management
48359 Renaming and committing a file on one PC when already open on a second, would result in the document being removed from the project when committed from the latter.
49007 It was not possible to place a Comment on a managed schematic sheet in Altium Designer. (BC:17869)
49607 Changing the case of letter(s) in a version-controlled document name would give a VCS 'File already exists' error. (BC:18081)
49618 Comparison of local documents and a project commit or release has been implemented.
49716 When connecting to a specific Workspace with certain time and date settings, Altium Designer would display an Error dialog stating that the local time was invalid.
49849 A new warning is presented when attempting to save a managed project to the active Workspace and duplicate project files are present in the design repository.
49850 General tasks are now listed in a separate group in the Comments and Tasks panel.
49892 When releasing a specific project using the Project Releaser, managed OutJob files would get unusual characters added to the beginning of a file name. (BC:18386)
49928 When placing from the Components panel some users would see a 'Store update, insert, or delete statement affected an unexpected number of rows (0)' error message.
Import/Export
46928 If the Windows decimal separator was set to the comma character, design constraints were not being imported during import of a Mentor Xpedition file.
Simulation
50053 Added the ability to present the Y-axis in Logarithmic form for simulation results in the Sim Data Editor, in the same way previously only possible for the X-axis.
50074 A set of seven quick-start simulation examples has been added to the UsersPublicDocumentsAltium\ExamplesSimulation Quick Start folder.
Other
49788 The following exception was being encountered: "EOleException. Object reference not set to an instance of an object in Altium.Edp.ComponentSearch.Plugin.dll."

Download